Loading...
User Guide 1076
Configuration Example
Verify SNMP view configurations:
Switch_A(config)#show snmp-server view
No. View Name Type MOID
--- -------------- ------- -------------------
1 viewDefault include 1
2 viewDefault exclude 1.3.6.1.6.3.15
3 viewDefault exclude 1.3.6.1.6.3.16
4 viewDefault exclude 1.3.6.1.6.3.18
5 View include 1
Verify SNMP group configurations:
Switch_A(config)#show snmp-server group
No. Name Sec-Mode Sec-Lev Read-View Write-View Notify-View
--- ------------- ----------- ---------- --------------- ------------ ----------
1 nms-monitor v3 authPriv View View
Verify SNMP user configurations:
Switch_A(config)#show snmp-server user
No. U-Name U-Type G-Name S-Mode S-Lev A-Mode P-Mode
--- ----------- ------ ------ ------ ----- ------ ------
1 admin remote nms-monitor v3 authPriv SHA DES
Verify SNMP host configurations:
Switch_A(config)#show snmp-server host
No. Des-IP UDP Name SecMode SecLev Type Retry Timeout
--- ---------------- ----- -------- --------- ---------- ------- ----- --------
1 172.168.1.222 162 admin v3 authPriv inform 3 100
Verify RMON statistics configurations:
Switch_A(config)#show rmon statistics

Table of Contents