Configuring L2PT L2PT Configuration
User Guide
487
Protocol Specify the Layer 2 protocol types of the packets that can be transparently
transmitted on the selected port:
STP: Enable protocol tunneling for the STP packets.
GVRP: Enable protocol tunneling for the GVRP packets.
01000CCCCCCC: Enable protocol tunneling for the packets with their destination
MAC address as 01000CCCCCCC, which includes CDP, VTP, PAgP and UDLD.
01000CCCCCCD: Enable protocol tunneling for the PVST+ packets with the
destination MAC address as 01000CCCCCCD.
LACP: Enable protocol tunneling for the LACP packets.
All: All the above Layer 2 protocols are supported for tunneling.
Threshold Specify the maximum number of packets to be processed for the specified
protocol on the port in one second. When the threshold is exceeded, the port
drops the specified Layer 2 protocol packets.
This value ranges from 1 to 1000 (packets per second). 0 indicates that the
threshold feature is disabled.
LAG Displays the LAG that the port is in.
3) In the Port Config section, configure the port that is connected to the ISP network as
an NNI port. Note that the protocols and threshold cannot be configured on the NNI
port.
Port Displays the port number.
Type Select NNI as the port type for the selected port. Usually, NNI port is connected
to the ISP network.
The default setting is None, which indicates that L2PT is disabled on this port.
LAG Displays the LAG that the port is in.
4) Click Apply.
Note:
The member port of an LAG (Link Aggregation Group) follows the configuration of the LAG and not its
own. The configurations of the port can take effect only after it leaves the LAG.
2.2 Using the CLI
Follow these steps to configure L2PT feature.
Step 1 configure
Enter global configuration mode.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TP-Link T2600G Series and is the answer not in the manual?

TP-Link T2600G Series Specifications

General IconGeneral
ModelT2600G Series
LayerLayer 2+
TypeManaged
Uplink Ports4 x Gigabit SFP slots
VLAN4K VLANs
QoS8 priority queues
ManagementWeb-based GUI, CLI, SNMP, RMON
Standards and ProtocolsIEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3ad, IEEE 802.3x, IEEE 802.1d, IEEE 802.1s, IEEE 802.1w, IEEE 802.1q, IEEE 802.1p, IEEE 802.3af, IEEE 802.3at
InterfaceRJ45
L2 FeaturesSTP, RSTP, MSTP, LACP, IGMP Snooping
L3 FeaturesStatic Routing
Security802.1X, Port Security, DHCP Snooping, IP Source Guard, DoS Defend, ARP Inspection, SSH, SSL, ACL
MAC Address Table16K
Jumbo Frame9KB
Operating Temperature0°C to 40°C
Storage Temperature-40°C to 70°C
Operating Humidity10% to 90% RH non-condensing