Configuring QoS Configuration Examples
User Guide
669
Switch_A#show qos cos-map
-----+-----+-----+-----+-----+-----+-----+----+----
Tag |0 |1 |2 |3 |4 |5 |6 |7
-----+-----+-----+-----+-----+-----+-----+----+----
TC |TC1 |TC0 |TC2 |TC4 |TC4 |TC5 |TC6 |TC7
-----+-----+-----+-----+-----+-----+-----+----+----
Verify the scheduler mode of the egress port:
Switch _A#show qos queue interface gigabitEthernet 1/0/3
Gi1/0/3----LAG: N/A
Queue Schedule Mode Weight Min Bandwidth(%)
----- ---------- ----- ----------
TC0 WRR 1 0%
TC1 WRR 5 0%
TC2 WRR 1 0%
TC3 WRR 1 0%
TC4 WRR 1 0%
TC5 WRR 1 0%
TC6 WRR 1 0%
TC7 WRR 1 0%
6.2 Example for Voice VLAN
6.2.1 Network Requirements
As shown below, the company plans to install IP phones in the office area. To ensure the
good voice quality, IP phones and the computers will be connected to the different ports of
the switch, and the voice traffic requires a higher priority than the data traffic.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TP-Link T2600G Series and is the answer not in the manual?

TP-Link T2600G Series Specifications

General IconGeneral
ModelT2600G Series
LayerLayer 2+
TypeManaged
Uplink Ports4 x Gigabit SFP slots
VLAN4K VLANs
QoS8 priority queues
ManagementWeb-based GUI, CLI, SNMP, RMON
Standards and ProtocolsIEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3ad, IEEE 802.3x, IEEE 802.1d, IEEE 802.1s, IEEE 802.1w, IEEE 802.1q, IEEE 802.1p, IEEE 802.3af, IEEE 802.3at
InterfaceRJ45
L2 FeaturesSTP, RSTP, MSTP, LACP, IGMP Snooping
L3 FeaturesStatic Routing
Security802.1X, Port Security, DHCP Snooping, IP Source Guard, DoS Defend, ARP Inspection, SSH, SSL, ACL
MAC Address Table16K
Jumbo Frame9KB
Operating Temperature0°C to 40°C
Storage Temperature-40°C to 70°C
Operating Humidity10% to 90% RH non-condensing
Storage Humidity5% to 90% non-condensing