Configuring DHCP Service DHCP Server Configuration
User Guide
551
Switch(dhcp-config)#show ip dhcp server pool
Pool Name: pool1
Network Address: 192.168.1.0
Subenet Mask: 255.255.255.0
Lease Time: 180
Default Gateway: 192.168.1.1
DNS Server: 192.168.1.4
Netbios Server: 192.168.1.19
Netbios Node Type: b-node
Next Server Address: 192.168.1.30
Domain Name: com
Bootfile Name: bootfile
Switch(dhcp-config)#end
Switch#copy running-config startup-config
2.2.3 Configuring Manual Binding
Some hosts, WWW server for example, requires a static IP address. To satisfy this
requirement, you can manually bind the MAC address or client ID of the host to an IP
address, and the DHCP server will reserve the bound IP address to this host at all times.
Follow these steps to configure Manual Binding:
Step 1 configure
Enter Global Configuration Mode.
Step 2 ip dhcp server pool
name
Create a DHCP server pool and enter DHCP Configuration Mode.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TP-Link T2600G Series and is the answer not in the manual?

TP-Link T2600G Series Specifications

General IconGeneral
ModelT2600G Series
LayerLayer 2+
TypeManaged
Uplink Ports4 x Gigabit SFP slots
VLAN4K VLANs
QoS8 priority queues
ManagementWeb-based GUI, CLI, SNMP, RMON
Standards and ProtocolsIEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3ad, IEEE 802.3x, IEEE 802.1d, IEEE 802.1s, IEEE 802.1w, IEEE 802.1q, IEEE 802.1p, IEEE 802.3af, IEEE 802.3at
InterfaceRJ45
L2 FeaturesSTP, RSTP, MSTP, LACP, IGMP Snooping
L3 FeaturesStatic Routing
Security802.1X, Port Security, DHCP Snooping, IP Source Guard, DoS Defend, ARP Inspection, SSH, SSL, ACL
MAC Address Table16K
Jumbo Frame9KB
Operating Temperature0°C to 40°C
Storage Temperature-40°C to 70°C
Operating Humidity10% to 90% RH non-condensing
Storage Humidity5% to 90% non-condensing