EasyManuals Logo

TP-Link T2600G Series User Manual

TP-Link T2600G Series
1136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #431 background imageLoading...
Page #431 background image
User Guide 402
Configuring Spanning Tree STP/RSTP Configurations
Switch(config)#show spanning-tree active
Spanning tree is enabled
Spanning-tree’s mode: RSTP (802.1w Rapid Spanning Tree Protocol)
Latest topology change time: 2006-01-02 10:04:02
Root Bridge
Priority : 32768
Address : 00-0a-eb-13-12-ba
Local bridge is the root bridge
Designated Bridge
Priority : 32768
Address : 00-0a-eb-13-12-ba
Local Bridge
Priority : 32768
Address : 00-0a-eb-13-12-ba
Interface State Prio Ext-Cost Int-Cost Edge P2p Mode
--------- -------- ---- -------- -------- ---- --------- -----
Gi1/0/16 Enable 128 200000 200000 No Yes(auto) Rstp
Gi1/0/18 Enable 128 200000 200000 No Yes(auto) Rstp
Gi1/0/20 Enable 128 200000 200000 No Yes(auto) Rstp
Role Status LAG
----- ------- ------
Desg Fwd N/A
Desg Fwd N/A
Desg Fwd N/A
Switch(config)#end
Switch#copy running-config startup-config

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TP-Link T2600G Series and is the answer not in the manual?

TP-Link T2600G Series Specifications

General IconGeneral
ModelT2600G Series
LayerLayer 2+
TypeManaged
Uplink Ports4 x Gigabit SFP slots
VLAN4K VLANs
QoS8 priority queues
ManagementWeb-based GUI, CLI, SNMP, RMON
Standards and ProtocolsIEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3ad, IEEE 802.3x, IEEE 802.1d, IEEE 802.1s, IEEE 802.1w, IEEE 802.1q, IEEE 802.1p, IEEE 802.3af, IEEE 802.3at
InterfaceRJ45
L2 FeaturesSTP, RSTP, MSTP, LACP, IGMP Snooping
L3 FeaturesStatic Routing
Security802.1X, Port Security, DHCP Snooping, IP Source Guard, DoS Defend, ARP Inspection, SSH, SSL, ACL
MAC Address Table16K
Jumbo Frame9KB
Operating Temperature0°C to 40°C
Storage Temperature-40°C to 70°C
Operating Humidity10% to 90% RH non-condensing
Storage Humidity5% to 90% non-condensing

Related product manuals