User Guide 438
Configuring Spanning Tree Configuration Example for MSTP
Interface Prio Cost Role Status LAG
--------- ---- -------- ------ ----- ----
Gi1/0/1 128 300000 Root Fwd N/A
Gi1/0/2 128 200000 Altn Blk N/A
Verify the configurations of Switch A in instance 2:
Switch(config)#show spanning-tree mst instance 2
MST-Instance 2
Root Bridge
Priority : 0
Address : 3c-46-d8-9d-88-f7
Internal Cost : 200000
Root Port : 2
Designated Bridge
Priority : 0
Address : 3c-46-d8-9d-88-f7
Local Bridge
Priority : 32768
Address : 00-0a-eb-13-23-97
Interface Prio Cost Role Status LAG
--------- ---- -------- ------- ------- ----
Gi1/0/1 128 200000 Desg Fwd N/A
Gi1/0/2 128 200000 Root Fwd N/A
Switch B
Verify the configurations of Switch B in instance 1:
Switch(config)#show spanning-tree mst instance 1
MST-Instance 1
Root Bridge
Priority : 0
Address : 00-0a-eb-13-12-ba

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TP-Link T2600G Series and is the answer not in the manual?

TP-Link T2600G Series Specifications

General IconGeneral
ModelT2600G Series
LayerLayer 2+
TypeManaged
Uplink Ports4 x Gigabit SFP slots
VLAN4K VLANs
QoS8 priority queues
ManagementWeb-based GUI, CLI, SNMP, RMON
Standards and ProtocolsIEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3ad, IEEE 802.3x, IEEE 802.1d, IEEE 802.1s, IEEE 802.1w, IEEE 802.1q, IEEE 802.1p, IEEE 802.3af, IEEE 802.3at
InterfaceRJ45
L2 FeaturesSTP, RSTP, MSTP, LACP, IGMP Snooping
L3 FeaturesStatic Routing
Security802.1X, Port Security, DHCP Snooping, IP Source Guard, DoS Defend, ARP Inspection, SSH, SSL, ACL
MAC Address Table16K
Jumbo Frame9KB
Operating Temperature0°C to 40°C
Storage Temperature-40°C to 70°C
Operating Humidity10% to 90% RH non-condensing
Storage Humidity5% to 90% non-condensing