User Guide 966
Configuring sFlow (Only for Certain Devices) sFlow Configuration
Choose the menu MAINTENANCE > sFlow> sFlow Sampler to load the following page.
Figure 2-3 Configuring the sFlow Sampler
Follow these steps to configure the sFlow Sampler:
1) Set one or more ports to be Samplers and configure the relevant parameters . One port
can be bound to only one collector.
Collector ID Choose a collector to be bound with the port.
Ingress Sampling
Rate (Hz)
Specify the ingress sampling frequency; the sampler takes one packet out of the
specified number of packets. Valid values are from 1024 to 65535. The default is
0 which means no packets will be sampled.
Egress Sampling
Rate (Hz)
Specify the egress sampling frequency; the sampler takes one packet out of the
specified number of packets. Valid values are from 1024 to 65535. The default is
0 which means no packets will be sampled.
Maximum Header
Size (Bytes)
Specify the maximum number of bytes that should be copied from a sampled
packet. Valid values are from 18 to 256 bytes and the default is 128 bytes.
LAG Displays the LAG the port belongs to.
2) Click Apply.