Policy Classification Configuration Command Set
Assigning Classification Rules to Policy Profiles
8-12 Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide
Command Mode
Read-Write.
Examples
This example shows how to use Table 8-2 to create (and enable) classification rule number 1. This
rule will classify Ethernet II Type 1526 frames to VLAN 7 on the ports assigned to policy 1:
This shows how to set a classification rule that permits Ethernet II Type 1526 frames to be
forwarded on all VLANs:
This example shows how to use Table 8-2 to create (and enable) classification rule number 5. This
rule specifies that UDP frames from source port 45 will be filtered from VLAN 7 on ports assigned
to policy profile 8:
Table 8-2 provides the set policy classify data_values that can be entered for a particular
classification type, and the data_mask that can be entered for each classifier associated with that
parameter.
Matrix>set policy classify 1 1 vlan 7 ether 1526
Matrix>set policy classify 2 2 vlan 4095 ether 1526
Matrix>set policy classify 8 5 vlan 7 udpportsource 45
NOTE: VLAN classification is available for Ethernet II type (ether) and 802.3 SAP (llc)
frames. Untagged frames received with any of the other VLAN classification protocols
listed in Tabl e 8 -2
will be dropped and not forwarded.
Table 8-2 Valid Values for Policy Classification
Classification Parameter data_value data_mask
ether Type field in Ethernet II
packet:
0x600 - 0xffff
Not applicable.
llc DSAP/SSAP pair in 802.3
type packet field:
0 - 65535
Not applicable.