Policy Classification Configuration Command Set
Assigning Classification Rules to Policy Profiles
8-12 Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide
Command Mode
Read-Write.
Examples
This example shows how to use Table 8-2 to create (and enable) classification rule number 1. This 
rule will classify Ethernet II Type 1526 frames to VLAN 7 on the ports assigned to policy 1:
This shows how to set a classification rule that permits Ethernet II Type 1526 frames to be 
forwarded on all VLANs:
This example shows how to use Table 8-2 to create (and enable) classification rule number 5. This 
rule specifies that UDP frames from source port 45 will be filtered from VLAN 7 on ports assigned 
to policy profile 8:
Table 8-2 provides the set policy classify data_values that can be entered for a particular 
classification type, and the data_mask that can be entered for each classifier associated with that 
parameter.
Matrix>set policy classify 1 1 vlan 7 ether 1526
Matrix>set policy classify 2 2 vlan 4095 ether 1526
Matrix>set policy classify 8 5 vlan 7 udpportsource 45 
NOTE: VLAN classification is available for Ethernet II type (ether) and 802.3 SAP (llc) 
frames. Untagged frames received with any of the other VLAN classification protocols 
listed in Tabl e 8 -2
 will be dropped and not forwarded.
Table 8-2 Valid Values for Policy Classification
Classification Parameter data_value data_mask
ether  Type field in Ethernet II 
packet:
0x600 - 0xffff
Not applicable.
llc  DSAP/SSAP pair in 802.3 
type packet field: 
0 - 65535
Not applicable.