Remote Control Commands
R&S
®
SMW200A
942User Manual 1175.6632.02 ─ 16
Parameters:
<Mode> UNCHanged | ERMS
*RST: UNCHanged
Example: See Example "Creating a multi-segment waveform" on page 922
Manual operation: See "Level" on page 336
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:OFILe <OFile>
Defines the file name of the output multi-segment waveform.
Parameters:
<OFile> string
Example: See Example "Creating a multi-segment waveform" on page 922
Manual operation: See "Save List/Save List As..." on page 332
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:SEGMent:APPend
<Waveform>
Appends the specified waveform to the configuration file.
Setting parameters:
<Waveform> string
Example: see Example "Creating a multi-segment waveform" on page 922
Usage: Setting only
Manual operation: See "Multi Segment Table, Append/Delete/Shift Seg."
on page 334
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:SEGMent:CATalog?
Queries the segments of the currently selected configuration file.
Return values:
<Catalog> string
Example: see Example "Creating a multi-segment waveform" on page 922
Usage: Query only
Manual operation: See "Multi Segment Table, Append/Delete/Shift Seg."
on page 334
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:SELect <Filename>
Selects a configuration file from the default directory. If a configuration file with the
specified name does not yet exist, it is created. The file extension *.inf_mswv may
be omitted.