Issue 3.0
2-26 SV9100 System Specifications
SECTION 6 SYSTEM REQUIREMENTS AND SPECIFICATIONS
6.1 Cabling
This section provides cabling requirements and specifications for various
equipment used in the SV9100 system.
Figure 2-3 Connecting the DLC Using Twisted 2-Pair Cable is a diagram of the
chassis connected with each of the multiline terminals and single line telephones
by a separate twisted 1-pair cable or 2-pair cable (only for multiline terminals).
Refer to the following tables for cabling requirements and specifications.
Table 2-16 DT300/DT400 Series Loop Resistance and Cable Length on
page 2-26
Table 2-17 DT700/DT800 Series Loop Resistance and Cable Length on
page 2-27
Table 2-18 Cable Connection Between Analog Port and Single Line
Equipment on page 2-28
Table 2-19 Cabling Requirements on page 2-29
Figure 2-3 Connecting the DLC Using Twisted 2-Pair Cable
Table 2-16 DT300/DT400 Series Loop Resistance and Cable Length
Terminal or Adapter
By Twisted 1-Pair Cable
(without AC Adapter)
24 AWG
DTL-2E-1 (BK) TEL
1,969 ft (600m)
DTL-6DE-1 (BK) TEL
1,969 ft (600m)
DTL-12E-1 (BK) TEL
1,969 ft (600m)
DTL-8LD-1 (BK) TEL
DTL-8LD-1 (WH) TEL
1,969 ft (600m)
DTL-12BT-1 (BK) TEL
1,969 ft (600m)
DTL-12PA-1 (BK) TEL
1,969 ft (600m)
DTL-12D-1 (BK) TEL
DTL-12D-1 (WH) TEL
1,969 ft (600m)
Multiline Terminal
Twisted 2-Pair Cable
DLC
RJ-11