Issue 3.0
2-30 SV9100 System Specifications
VA @ 120V: Base chassis = 263VA, Expansion chassis=263VA,
total 1052VA
KWh @ AC Input I x 120V/1000: Base chassis = 0.263 KWh,
Expansion chassis = 0.263 KWh, total 1.052 KWh
BTU (KWh) x 3413): Base Chassis = 898BTU,
Expansion Chassis= 898BTU, total 3592 BTU
A dedicated outlet, separately fused and grounded for each chassis
should be installed
6.2.2 Power Supply Consumption
Table 2-20 Chassis Power Consumption provides power consumption
information for the SV9100 chassis.
Double Pole/Neutral Fusing
(power supply fuses are located at both the L and N
side).
Table 2-20 Chassis Power Consumption
Chassis
Maximum
RMS
Current
Watts Used
(Idle)
Watts Used
(Maximum)
Basic Chassis – GCD-CP10 Chassis
2.19A 96 130
Basic Chassis + Expansion Chassis
4.38A 192 260
Basic Chassis + 2 Expansion Chassis
6.57A 288 390
Basic Chassis + 3 Expansion Chassis
8.76A 384 520