Issue 3.0
5-76 Installing DT Series Digital and IP Multiline Terminals
5.2.4.2 Configuring the Digital Telephone for the Correct
Number of Line Keys
1. With the telephone not plugged in and the handset on-hook,
press the 4 and 6 buttons on the numbered keypad and
connect the telephone cable.
This places the telephone into Service Class Read/
Write (R/W) mode. The Message Waiting (MW) LED
should be On.
2. Press 1 to enter the Line Key Type mode.
The Message Waiting LED should flash.
3. Follow the directions below for the type of line key module
installed:
4. Save to memory by pressing line key 2, 8, 14 or 20. The
display changes back to the Service Class R/W mode and
the Message Waiting (MW) LED is On Red.
5. Press Exit to return the telephone to idle.
5.2.4.3 Configuring the IP Telephone for the Correct Number of
Line Keys
1. Press Menu, then 0 (Config) to enter the terminal program
mode.
2. At the Login screen, enter the user name (default = ADMIN)
and password (default = 6633222) and press the OK
Softkey.
3. Press 3 for Maintenance Setting.
4. Press 4 for Adjust.
5. Press 2 for Key Kit Type.
6. Press the Up/Down key to select the Key Kit.
Table 5-14 Line Key Type
Line Key Type Push
2-Button
1
6-Button
2
8-Button
3
12-Button
4
24-Button
5
Table 5-15 Ten Key Kit Type
Ten Key Kit Entry Description
Kit1
Type A – Japan with cursor key
Kit2
Type A – US with cursor key