Issue 3.0
4-74 Installing the SV9100 Blades
5.5.4 Connectors
The CN2 connector provides connection to four analog DID trunk ports,
which are polarity sensitive (tip-to-tip, ring-to-ring). The OPX circuits,
however, are not polarity sensitive. The GCD-4DIOPA requires one
universal slot. (Refer to Figure 4-25 GCD-4DIOPA Blade on page 4-72.) If
Program 10-03-01 has OPX defined, note that the blade consumes four
(4DIOPA) trunks and extension ports when installed. If OPX is not defined,
then only trunks ports are consumed.
Table 4-31 GCD-4DIOPA RJ-61 Cable Connector Pin-Outs shows the
pin-outs for the RJ-61 connector. Figure 4-25 GCD-4DIOPA Blade on page
4-72 shows the location of the connectors on the 4DIOPA blade.
Off
On
Unit Busy
A Channel is busy (use
another from CH1 ~ CHx).
Off
All channels are idle.
Flash 80ms (On/
Off) x 3/400ms
Off
Downloading firmware.
Table 4-30 GCD-4DIOPA LED Indications (Continued)
LED Indication
Operation Status Remarks
Live LED
(Green)
Busy LED (Red)
Table 4-31 GCD-4DIOPA RJ-61 Cable Connector Pin-Outs
RJ-61 Cable Connector – CN2
Line No. Pin No. Connection
15 Tip
4Ring
23 Tip
6Ring
32 Tip
7Ring
41 Tip
8Ring