Issue 3.0
SV9100 System Hardware Manual 7-17
The advantage of Power over Ethernet is that you can provide
the DAPs with power from one location only, e.g., same power
source as the SV9100. On such a location you can install a
UPS (Uninterruptable Power Supply) to increase system
reliability.
3. Connect the other end of the cable to your TCP/IP network.
During the boot process the LEDs will flash on and off. When
LED is solid Yellow it is operational and synchronized to other
DAP or is the synchronization master (refer to Table 7-8 Base
Station LED States and Meanings).
Table 7-6 DAP RJ-45 Pinouts
DAP RJ-45 Socket
Pin No. Connection
1 10/100 Base-T Tx+
2 10/100 Base-T Tx-
3 10/100 Base-T Rx+
4 +48 Volt power
5 +48 Volt power
6 10/100 Base-T Rx–
7 RTN (0 Volt) power
8 RTN (0 Volt) power
Table 7-7 AP300/AP400 LED Indications
Flash Pattern Condition Indicated
Off No Power.
0.5 Seconds On –
0.5 Seconds Off
Loading software/firmware.
Short Flash every 2.5
Seconds
IP Network error (not connected, no DHCP/
TFTP server, no DAP controller).
Steady On DAP Operational and synchronized to other
DAP or is the synchronization master.
Continuous Fast Blink Hardware error.
Fast Blink DAP operational, but trying to synchronize to
another DAP.