Issue 3.0
SV9100 System Hardware Manual 9-125
13.3.2 Installing the ADA-L UNIT
Perform the following steps to connect the ADA-L UNIT to the Bottom
Option Interface located underneath the DTL/ITL multiline terminal.
1. Unplug the line cord from the multiline terminal.
2. Turn the DTL/ITL multiline terminal upside down.
3. Lower the tilt leg to the first position (refer to Figure 9-105 Separate
Tilt Leg from Leg Support).
4. Push the two stopper tabs through the slots to separate the tilt leg
from the leg support.
5. Lay the tilt leg and the leg support flat to expose ADA-L UNIT
compartment.
6. Carefully pry loose the knockout covering the bottom option interface
(refer to Figure 9-106 Bottom Option Interface Knockout on page
9-126).
IMPORTANT
Only ONE ADA-L UNIT can be installed at a time.
WARNING
To prevent possible damage to the ADA-L UNIT or the DTL/
ITL multiline terminal during installation or removal,
disconnect the line cord/LAN cable and the AC/DC adapter
from the DTL/ITL multiline terminal.
Figure 9-105 Separate Tilt Leg from Leg Support
Stoppers
Tilt Leg