EasyManua.ls Logo

NEC Univerge SV9100 - Table 4-18 GPZ-4 LCA;GPZ-8 LCE; RJ-61 Cable Connector Pin-Outs

NEC Univerge SV9100
740 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue 3.0
SV9100 System Hardware Manual 4-45
Each CN2 (GPZ-4LCA/GPZ-8LCE) or CN3 (GPZ-8LCE only) connector
provides connection to four analog station ports and is not polarity sensitive.
The GPZ-8LCE consumes eight ports ranging between ports 001~256
(remember that the GCD-8LCA consumes eight ports).
Refer to the following tables for maximum upgrade capacity of the
GPZ-4LCA/GPZ-8LCE SLI daughter board:
Table 2-6 SV9100 Maximum 9.5” Gateway and 19” System
Capacities – Blades on page 2-12
Table 2-7 SV9100 Maximum 9.5” Base and Expansion System
Capacities – Blades on page 2-14
4.4.2 Installation
This daughter board can be installed on the GCD-4LCA or GCD-8LCA
blade.
To install the GPZ-4LCA
/GPZ-8LCE:
1. Four plastic spacers are Included with the GPZ-4LCA/GPZ-8LCE.
Install the plastic spacers on either the GCD-4LCA or GCD-8LCA.
Make sure to attach the spacers so that they extend out on the side of
the daughter board which has the CN1 connector. Refer to Figure
4-17 Installing the GPZ-4LCA/GPZ-8LCE Daughter Board on page
4-44.
2. Position the GPZ-4LCA
/GPZ-8LCE CN1 connector over the CN4
connector on the GCD-4LCA/GCD-8LCA blade. Press the blade and
board together, ensuring the plastic spacers lock in place. Refer to
Figure 4-17 Installing the GPZ-4LCA/GPZ-8LCE Daughter Board on
page 4-44.
3. Install the GCD-4LCA/GCD-8LCA blade in the slot in the chassis.
4.4.3 Connectors
Table 4-18 GPZ-4LCA/GPZ-8LCE/ RJ-61 Cable Connector Pin-Outs on
page 4-46 show the pin-outs for the RJ-61 connector. Figure 4-17 Installing
the GPZ-4LCA/GPZ-8LCE Daughter Board on page 4-44 shows the
location of the connectors on the GPZ-4LCA
/GPZ-8LCE daughter boards.
CAUTION
When connecting a fax machine or analog modem, make
sure to set Program 15-03-03 to 1 (special terminal) to
avoid communication problems.
The GCD-4LCA/GCD-8LCA blade and the GPZ-4LCA/
GPZ-8LCE daughter board are categorized as TNV2. With
this designation, off-premise wiring is not acceptable. Any
cabling to these blades or daughter boards must be in the
building – no outside cabling is permitted.
Branch connection is not acceptable.

Table of Contents