Issue 3.0
4-38 Installing the SV9100 Blades
Refer to the following tables for maximum upgrade capacities of the
GPZ-8DLCB daughter board:
Table 2-6 SV9100 Maximum 9.5” Gateway and 19” System
Capacities – Blades on page 2-12
Table 2-7 SV9100 Maximum 9.5” Base and Expansion System
Capacities – Blades on page 2-14
4.2.2 Installation
The GPZ-8DLCB is installed on the GCD-8DLCA. To install:
1. Connect the GPZ-8DLCB to the CN2 connector on the GCD-8DLCA
blade. Refer to Figure 4-14 GCD-8DLCA/GCD-16DLCA Blade on
page 4-33 for the location of the connectors on the blade.
2. Install the GCD-8DLCA into a slot.
3. Each CNx01 connector (CN101, CN201, CN301, CN401) is used to
connect up to four digital extensions.
4.2.3 GPZ-8DLCB Daughter Board Cable Connection
The GPZ-8DLCB blade has connections for CN301 and CN401. Refer to
Figure 4-14 GCD-8DLCA/GCD-16DLCA Blade on page 4-33 for connector
locations.
The following tables show the cable connections of the two RJ-61
connectors on the GPZ-8DLCB.
Table 4-15 GPZ-8DLCB RJ-61 Cable Connector Pin-Outs
RJ-61 Cable Connector
CN301 (ports 9~12)
Pin No. Connection
1
(T4) Tip for port 12
2
(T3) Tip for port 11
3
(T2) Tip for port 10
4
(R1) Ring for port 9
5
(T1) Tip for port 9
6
(R2) Ring for port 10
7
(R3) Ring for port 11
8
(R4) Ring for port 12