Issue 3.0
4-22 Installing the SV9100 Blades
3.1.3 Switch Settings
Refer to Table 4-6 GCD-CP10 Switch Settings for system restart/system
reset and with system power on. Figure 4-6 GCD-CP10 Blade Layout on
page 4-15 shows the location of the LOAD (S5) switch on the GCD-CP10
blade.
Table 4-6 GCD-CP10 Switch Settings
USB Memory Status Operation
Switch
S5 – LOAD
Switch
With a system restart or a system reset while holding
the LOAD (S5) switch:
When USB Memory is not
installed:
Cold Start occurs.
Database default occurs
When USB Memory is
installed:
USB Memory contents loaded.
When an unauthorized USB
device is installed:
System does not start and an
Illegal USB device is connected
alarm is recorded.
Table 4-7 GCD-CP10 Switch 4/6 Settings
Configuration Notes
SW4-1
ON Not Used
SW4-2
OFF Test Mode
ON = Test Mode
OFF = Normal
SW4-3
OFF RS232C Select
ON = Use
OFF = Not Used
SW4-4
ON Reset Configuration
ON = Normal
OFF = ICE Mode
S6
SENSE Switch Not Used