EasyManua.ls Logo

NEC Univerge SV9100 - Table 4-30 GCD-4 DIOPA LED Indications

NEC Univerge SV9100
740 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue 3.0
SV9100 System Hardware Manual 4-73
The GCD-4DIOPA provides:
Four (DIOPA) DID trunk circuits or four OPX circuits
Two Blade status LEDs
-48VDC
Refer to the following tables for maximum upgrade capacities of the
GCD-4DIOPA blade:
Table 2-6 SV9100 Maximum 9.5” Gateway and 19” System
Capacities – Blades on page 2-12
Table 2-7 SV9100 Maximum 9.5” Base and Expansion System
Capacities – Blades on page 2-14
5.5.2 Installation
The GCD-4DIOPA can be installed in any universal slot.
5.5.3 LED Indications
LED indications for the GCD-4DIOPA are listed in Table 4-30 GCD-4DIOPA
LED Indications. Each LED is listed with its associated function and LED
and Operational status.
Refer to Figure 4-25 GCD-4DIOPA Blade on page 4-72 for the location of
the LEDs on the blade.
Table 4-30 GCD-4DIOPA LED Indications
LED Indication
Operation Status Remarks
Live LED
(Green)
Busy LED (Red)
On
On System Initializing
Flash (1s) On The assignment of the unit is refused.
When you exceed the system
capacity.
When the main software version is
not matched.
Flash (1s) Trouble found during self-diagnostics.
Flash
(100ms)
On
Normal
Operation
A Channel is busy (use
another from CH1 ~ CHx).
Off
All channels are idle.