EasyManua.ls Logo

NEC Univerge SV9100 - Figure 9-108 ADA-L out Jack Connection

NEC Univerge SV9100
740 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue 3.0
SV9100 System Hardware Manual 9-127
13.3.3 ADA-L UNIT Connection
13.3.3.1 ADA-L UNIT Connection for Recording Only
10. Set the ADA-L UNIT DSW switches (Refer to Figure 9-104
ADA-L UNIT on page 9-123).
11. Using the mini-plug connection cord, connect the ADA-L
UNIT Out jack to the cassette recorder MIC jack (Refer to
Figure 9-108 ADA-L OUT Jack Connection on page 9-127)
.
13.3.3.2 ADA-L UNIT Connection for Sending Recorded Calls to
the Telephone
1. Set the ADA-L UNIT DSW switches (see Figure 9-104
ADA-L UNIT on page 9-123).
CAUTION
The mini-plug connection cord should not use an attenuator. Use a
monaural (single ring) mini-plug connection for normal recording.
NOTE
Set DSW 6 to ON.
DSW switch 5 is used to change the output
level from the OUT jack of the ADA-L
UNIT
(On = Low, Off = High).
Figure 9-108 ADA-L OUT Jack Connection
NOTE
Set DSW 6 to ON.
When sending recorded calls to the
telephone, set DSW switch 1 to ON.