Issue 3.0
2-12 SV9100 System Specifications
3.3 Blade Capacities
This is determined by the maximum blade configuration allowed. When installing
single line sets, DISA, or tie lines, CPU circuits must be allocated for DTMF
receivers. To install single line sets with CO/PBX line access, or when installing
immediate-start tie lines, CPU circuits must be allocated for dial tone detection.
Table 2-6 SV9100 Maximum 9.5” Gateway and 19” System Capacities – Blades
Hardware
9.5”
Chassis
19”
Chassis
with CPU
19”
Chassis
without
CPU
19”
Chassis
x4
Networked
Chassis
(NetLink)
Comments
Number of Slot(s) for Interface
Package
3 Slots 5 Slots 6 Slots 23 Slots
Common Control Blades:
GCD-CP10
11 01 50 –
GPZ-IPLE
(VoIP Daughter Board)
1 1 0 1 50 This unit provides
256 VOIP Gateway
channels
GCD-SVR2
(Server Blade)
11 11 1
Station Blades:
GCD-4DIOPA
(4 DID/OPX)
2 5 6 23 128 When installed as
an OPX blade
GCD-4LCA
(4 Single Line Telephone Interface)
25 623224 –
GCD-8LCA
(8 Single Line Telephone Interface)
25 623112 –
GCD-8DLCA
(8 Digital Station Interface)
25 623112 –
GCD-16DLCA
(16 Digital Station Interface)
25 62356 –
GPZ-8DLCB
(8 Digital Station Interface
Daughter Board)
25 62356 –
GPZ-4LCA
(4 Single Line Telephone Interface
Daughter Board)
25 62374 –
GPZ-8LCE
(8 Single Line Telephone Interface
Daughter Board)
25 62356 –
GCD-4LCF
(4 Single Line Telephone Interface)
25 623224