Issue 3.0
9-14 Installing SV9100 Optional Equipment
SECTION 5 EXTERNAL PAGING
5.1 External Page
Two external page zone/door box circuits are provided by each PGD(2)-U10 ADP
installed. Each Door Box/external page circuit provides a dry relay contact. The
GCD-CP10 also provides a connection for external paging and a relay. The
external page on the GCD-CP10 is speaker number 9 – the relay is number 0.
The external page speakers provided by the PGD(2)-U10 ADPs are 1~8 – the
relays on the PGD(2)-U10 ADPs are numbered 1~8.
The PGD(2)-U10 ADP can be used for talkback with External Page, as can a CO
trunk port with the proper external page equipment (ex: Valcom) – set Program
31-06-03 to 0 for talkback. However, the external page circuit on the GCD-CP10
cannot be used for talkback.
5.2 Installing an External Page System
1. Connecting to the GCD-CP10:
Connect an RCA line from the CN8 or CN9 connector on the GCD-CP10 to
the appropriate location on the extension cross-connect block.
2. Connect the two-conductor station cable from the cross-connect block to the
external relay/external page.
3. Install bridging clips as required.
-OR-
1. Connecting to the PGD(2)-U10 ADP:
Make sure the jumper in the PGD(2)-U10 ADP for the channel is set
correctly. (Refer to Figure 9-4 PGD(2)-U10 ADP Jumper Settings on page
9-4).
2. If a line cord was not previously connected to the PGD(2)-U10 ADP,
complete Steps 3-6. Otherwise, skip to Step 7.
3. Install a modular jack for each PGD(2)-U10 ADP. For each module, run
one-pair 24 AWG station cable from the cross-connect block to a modular
jack. Ground the unused pair.
4. Terminate the extension leads to GRN/RED of the modular jack. Terminate
the unused leads to the jack.
5. Install bridging clips as required.
6. Plug a modular line cord from the mod jack to the CN1 connector on the
PGD(2)-U10 ADP.
A PGD(2)-U10 ADP circuit used for External Paging cannot be used for
an analog Door Box.