Procedure
Issue 2.1 June 2006 1197
Adding control network cabling for the new circuit pack
To connect the duplicated IPSI slot to the control network:
1. Connect the TN2312BP I/O Adapter to the backplane amphenol connector that
corresponds to the slot in which the TN2312BP is installed.
2. Connect a CAT5 or better Ethernet cable to the RJ45 connector on the IPSI adapter.
3. Connect the other end of the CAT5 cable to the new, or alternate, Ethernet switch.
Verifying the IPSI circuit packs are inserted properly
To check that the IPSI circuit packs are inserted properly, perform the following steps:
1. After about 1 minute, open the SAT Circuit Packs screen using
display circuit-pack cabinetnumber. Verify that the TN2312B circuit packs are
shown in the appropriate slots.
Programming the duplicated IPSI circuit pack
Complete one of the following two steps for either DHCP addressing or static addressing. Use
DHCP addressing usually with dedicated control networks. Use static addressing usually with
non-dedicated control networks.
Note:
Note: Clear the ARP cache on the laptop before connecting to another IPSI by entering
arp -d 192.11.13.6 at the Windows command prompt.
1. For DHCP addressing, complete these steps:
Note:
Note: After you reseat the circuit pack, you must start the configuration operation within
5 seconds.
a. Reseat the IPSI circuit pack.
The display flashes.
b. Set the Switch ID and cabinet number by pressing the recessed button on the IPSI
faceplate.
!
CAUTION:
CAUTION: The display on the secondary IPSI must be exactly the same as that of the
existing IPSI. For example, if the IPSI in cabinet/carrier A reads A01, then the
IPSI in cabinet/carrier B must also read A01.

Table of Contents