Migration tasks
Issue 2.1 June 2006 637
Setting the alarm activation level
To set the alarm activation level:
1. Type change system-parameters maintenance. Press Enter.
2. In the CPE Alarm Activation Level field, select warning, minor, or major, depending on
the level that the customer wants. The default is none.
Backing up translations
To back up translations:
1. S8710: Place a formatted flash card in the compact flash drive attached to a USB port.
2. Start a Web browser.
3. Log in as craft or dadmin.
4. Click Launch Maintenance Web Pages.
5. Under Data Backup/Restore, click Backup Now.
6. Select the data sets and the backup method.
If you select Save ACP translations prior to backup, the media server automatically
saves the translations to the hard disk before the media server saves the translations to the
backup media.
7. Click Start Backup to start the backup process.
Migration tasks
Perform the following tasks to convert a processor port network to a port network (CMC).
Note:
Note: If you want to make the system high reliability, you cannot reuse the Compact
Modular Cabinets (CMCs). You must install Avaya G650 Media Gateways and
move all the circuit packs to the G650s.
Note:
Note: You must install the new Communication Manager license file on the media
server before you make the change or the system will not run.

Table of Contents