Migrating an Avaya IP600/S8100 to an S8700-Series Media Server with IP-PNC
866 Upgrading, Migrating, and Converting Media Servers and Gateways
Verifying IPSI connectivity
To verify IPSI connectivity:
1. Under Diagnostics, click Ping.
2. Under Endpoints to Ping, select IPSIs with cab number (1–99) ___ carrier number ___.
3. Type the correct cabinet and carrier numbers in the text boxes.
4. Click Execute Ping.
5. Verify that the endpoints respond correctly.
Enabling control of the IPSI
To enable control of the IPSI:
Note:
Note: Ensure that the IPSI has the same, current firmware.
!
CAUTION:
CAUTION: This procedure allows the media server to take control of the IPSI-controlled port
network(s). Failure to complete the steps correctly can result in no connection to
the network.
1. Type change system-parameters ipserver-interface. Press Enter.
The system displays IP Server Interface (IPSI) System Parameters window.
2. Set the IPSI Control of Port Networks: field to enabled
3. Press Enter to effect the change.
4. Type save translation. Press Enter.
The media server now controls all the port networks.
Verifying the customer data
The new translations must include all the media gateway and circuit pack administration. This
data includes the:
Media gateway
Circuit pack administration of the changed cabinets
Verify that the data is correct.