Post-migration administration
Issue 2.1 June 2006 867
Verifying circuit pack locations
To verify circuit pack locations:
1. Type list cabinet. Press Enter to view all the "cabinets." Verify that the cabinet number
assigned to the converted cabinets shows.
2. Type display cabinet number, where number is the cabinet number of the converted
cabinet. Press Enter. Under Carrier Description, Carrier Type verify that the number of
"carriers" in use matches the number of media gateways in the rack (G600 or G650).
Verifying circuit pack insertion
To verify circuit pack insertion:
1. To see the list of all the slot locations, type list configuration all. Press Enter.
2. Verify that the circuit pack code and vintage number appears in the Code and Vintage
fields. If No board appears in either field, a circuit pack was not installed in that slot.
Verifying the IP addresses
Ensure that the node names and IP addresses assigned to the TN2302AP IP Media Processor
circuit pack and the TN799DP C-LAN circuit pack are the same as before the migration.
To verify the IP addresses:
1. To get the node names for the TN2302AP IP Media Processor circuit pack and TN799DP
C-LAN circuit pack in the slots of interest, type display ip-interfaces. Press Enter.
2. To verify that the node names exist and that the IP addresses match the node names, type
list node-names. Press Enter.