On the active S8700 or S8710 Media Server
Issue 2.1 June 2006 957
Additional information:
● Type save translation and HELP. If [all or lsp] or [all or ess or lsp] displays,
type save translation all. Press Enter.
● Type save translation and HELP. If [lsp or [ip address]] displays, type save
translation lsp. Press Enter.
● Otherwise, type save translation. Press Enter.
To save translations, perform the following step:
● Type save translation. Press Enter.
If this operation is unsuccessful, follow the normal escalation procedures before continuing.
Checking the CNC status
Note:
Note: You can perform this step only if you have Communication Manager Release 3.0
or later.
If the system is using Control Network C (CNC), you need to check the CNC status.
To check the CNC status:
1. Access the server command line interface.
2. Log in as craft or dadmin.
3. Type cnc status. Press Enter.
The system displays one of the following messages:
Control Network C has not been configured.
Control Network C has been configured.
4. Record the CNC setting.
Recording the server connection type
To note the server connection type:
1. In a bash session, type grep -i offertype /etc/opt/ecs/ecs.conf. Press Enter.
2. Make a note of the server connection type.
sray = fiber-port network connectivity (PNC) (formerly multi-connect)
seagull = IP-PNC (formerly IP-connect)