Premigration administration
Issue 2.1 June 2006 557
● Verifying IPSI connectivity on page 573
● Verifying the customer data on page 573
● Verifying circuit pack locations on page 573
● Verifying circuit pack insertion on page 574
● Verifying the IP addresses on page 574
● Checking the link status on page 574
● Upgrading firmware on page 575
● Testing the installation on page 575
● Busying out previously busied out trunks on page 575
● Troubleshooting the migration on page 576
● Returning replaced equipment on page 576
Premigration administration
This migration is a service-affecting event. The CMCs must be turned off to replace the
processor and tone clock circuit packs. Before you turn off the cabinets, you must perform the
following premigration administration.
Connecting to the processor
To connect to the processor:
Note:
Note: You need a cross-over cable to connect your Services laptop directly to the
processor.
1. Perform one of the following actions to connect the Services laptop directly into the Avaya
IP600 processor circuit pack:
● If the processor circuit pack is a TN795, place the NIC card into the slot on the faceplate.
● If the processor circuit pack is a TN2314, plug the RJ45 connector directly into the RJ45
jack on the faceplate.
2. Start a terminal emulation application or Avaya Site Administration.
3. Log in as lucent3.