EasyManua.ls Logo

Avaya S8100 Series - Replacing the TN799 C C-LAN circuit pack; Installing TN771 Maintenance;Test; Migrating translations

Avaya S8100 Series
1262 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Migrating translations
Issue 2.1 June 2006 371
Replacing the TN799C C-LAN circuit pack
If you need to replace the TN799C C-LAN circuit pack:
1. Remove the TN799C Control-LAN (C-LAN) circuit pack.
2. Place the circuit pack in an antistatic carrier or bag. You might need to reinstall this circuit
pack if you must stop the migration.
3. Insert the new TN799DP C-LAN circuit pack into the same slot.
4. Replace the 259A adapter and CAT3 cable on the connector panel.
5. Use the Amphenol adapter that you used for the TN799 circuit pack and a CAT5 cable.
Installing TN771 Maintenance/Test
You can install a TN771 Maintenance/Test circuit pack in any slot other than slots A01 and A02.
Avaya recommends one TN771 Maintenance/Test circuit pack per location for the following
conditions:
There are three or more G650, G600, or CMC1 cabinets in the S8400 system. Do not
include G150 and H.248 gateways in this count, and
There are IP endpoints or ISDN endpoints. These endpoints consist of:
- BRI trunks
- PRI trunks
- BRI stations
The TN8412AP S8400 IP Interface (SIPI) circuit pack provides all maintenance functions that
were present on the TN798 or TN2402 Processor circuit pack. This carrier does not have a
TN775 Maintenance (EPN) dedicated slot.
Migrating translations
This section describes how to migrate the translation files from the current system to the S8400
Media Server.

Table of Contents

Related product manuals