Migration tasks
Issue 2.1 June 2006 339
Turning off power to all cabinets
!
CAUTION:
CAUTION: Ensure that you have done the premigration administration. For more
information, see Premigration administration
.
To turn off power to all cabinets:
● Turn off the power to each cabinet.
Removing circuit packs
To remove circuit packs from the CMC:
1. Remove the TN798B or TN2402 Processor circuit pack from slot A01.
2. Remove the TN2182 Tone Clock circuit pack from slot A02.
3. Remove the TN767 DS1 Interface circuit pack, if installed.
4. Remove the TN2207 DS1 Interface circuit pack, if installed.
5. Remove the TN2313 DS1 Interface circuit pack, if installed.
Inserting circuit packs
To install circuit packs into the CMC:
1. Install the TN8412AP S8400 IP Interface (SIPI) circuit pack into slot A02.
2. Install the TN8400AP Media Server circuit pack into slot A01.
3. If the system had a TN767, TN2207, or TN2313 DS1 Interface circuit pack, install the
TN464HP DSD1 Interface circuit pack in any open slot.