Checklist for converting a port network to duplicated TN2602AP IP Media Resource 320 circuit packs
Issue 2.1 June 2006 1209
Disabling an existing TN2602AP circuit pack or TN2302 circuit
packs
To remove any TN2302 circuit packs so you can reuse their slots, you must first disable them.
To convert an existing TN2602AP circuit pack from a load-balancing circuit pack to a standby
duplicated bearer circuit pack, you must first disable it.
Note:
Note: Disabling the TN2302 circuit packs is optional. However, all bearer traffic is
handled by the active TN2602AP circuit pack unless all channels are busy. Any
overflow traffic is then handled by any remaining TN2302 circuit packs.
To disable the TN2302 or TN2602AP circuit packs, if any, perform the following steps:
1. Type campon-busyout media-processor UUCSS, where UUCSS is the location of a
TN2302 circuit pack you are replacing or the TN2602AP you are converting, and press
Enter.
2. Wait until all calls the circuit pack is carrying have ended.
3. Type change ip-interface UUCSS, where UUCSS is the location of a TN2302 circuit
pack you are replacing or the TN2602AP circuit pack you are converting, and press Enter.
4. Type n in the Enable Ethernet Port field, and press Enter.
5. Type remove ip-interface UUCSS to remove the TN2302 or TN2602AP circuit pack
from Communication Manager software.
6. Repeat steps 1 through 5 for the additional TN2302 circuit packs you are removing.
Removing the TN2302 circuit pack hardware
To remove the TN2302 circuit pack hardware, if any, perform the following steps:
1. Unseat the TN2302 circuit pack from its slot.
2. Disconnect the network cable(s) to the ETHERNET connector on the TN2302AP backplane
adapter(s).
3. Disconnect the amphenol connector on the adapter from the amphenol connector
corresponding to each TN2302AP slot.
4. Repeat steps 1 through 3 for the next TN2302 circuit pack.