Migrating a DEFINITY Server SI Direct-Connect in an SCC to a Direct-Connect
502 Upgrading, Migrating, and Converting Media Servers and Gateways
To install the Expansion Interface circuit packs:
1. Remove the existing circuit pack.
2. Place the circuit pack in an antistatic carrier or bag.
3. Insert the TN570B Expansion Interface vintage 7 or later circuit pack into the EXPN INTFC
slots (A01, A02).
4. Repeat Steps 1 and 2 for each PN that does not contain TN570B Expansion Interface
vintage 7 or later circuit packs.
Turning on the media gateway
To turn on the media gateway:
1. Turn on the media gateways.
2. Remove the emergency ground wire if used.
Post-migration administration
Accessing the server command line interface with SSH protocol
Note:
Note: Using the SSH protocol to access the server is applicable to CM Release 3.0 and
forward.
To use this procedure with a laptop cable connection to the services port, you must configure
your laptop for the network connection. See Network configuration
on page 1242. In addition, a
third-party SSH client must already be installed on your computer.
PuTTY is one such client available for download from http://www.putty.nl/download.html
. The
following procedure describes, as an example of SSH access, how to log into the server
command line with PuTTY.