Converting simplex bearer to duplicated bearer on IP-PNC port networks (with S8700-series Media Servers
1218 Upgrading, Migrating, and Converting Media Servers and Gateways
3. Look at the LINKS and DSP CHANNEL STATUS categories to determine whether the call is
being processed.
4. Type set media-processor UUCSS, where UUCSS is the location of the standby
TN2602AP circuit pack.
The standby TN2602AP circuit pack becomes active.
5. Type status media processor board UUCSS, where UUCSS is the location of the
newly-active circuit pack.
The Media Processor Status screen appears. Under DSP CHANNEL STATUS, the test call
has moved to the column for the newly-active TN2602AP circuit pack.
Note:
Note: TN2602AP call processing and interchange activity is tracked through the
MEDPRO-C maintenance object. See Maintenance Alarms for Avaya
Communication Manager 3.1, Media Gateways and Servers, 03-300430, for
more information.
status media-processor board 1c03 Page 1 of 1
MEDIA-PROCESSOR STATUS
Duplication State: active Duplication State: standby
Board Location: 1c03 Board Locations: 1c07
Source IP Address: 192.168.22.11 Source IP Address: 192.168.22.51
Node Name: medpro1 Node Name: medpro2
Subnet Mask: 255.255.255.0 Subnet Mask: 255.255.255.0
Gateway Address: 192.168.22.255 Gateway Address: 192.168.22.255
MAC Address: 00:00:04:0d:05:03 MAC Address: 00:00:04:0d:05:07
Ethernet Enabled? yes Ethernet Enabled? yes
COMMON DUPLICATED VALUES
Links Alarms Standby Refreshed: yes Locked? no Links Alarms
mpcl: up mj: 0 Network Region: 1 mpcl: up mj: 0
eth: up mn: 0 Shared IP Address: 135.9.72.52 eth: up mn: 0
peer: up wn: 0 Shared Virt-MAC: 02:00:04:0d:05:18 peer: up wn: 0
DSP CHANNEL STATUS
DSP 1: in-service/active, 60 calls DSP 1: in-service/standby
DSP 2: in-service/active, 50 calls DSP 2: in-service/standby
DSP 3: in-service/active, 57 calls DSP 3: in-service/standby
DSP 4: in-service/active, 47 calls DSP 4: in-service/standby