EasyManua.ls Logo

Avaya S8100 Series - Page 804

Avaya S8100 Series
1262 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Migrating a DEFINITY ONE/S8100 to an S8700-Series Media Server with IP-PNC
804 Upgrading, Migrating, and Converting Media Servers and Gateways
For more information, see Migration paths on page 799.
When you are migrating from a DEFINITY system, complete the following additional tasks
before starting the migration:
9
Task Description
Determine which adapters
and cables you can reuse.
You cannot reuse the following items:
The C-LAN 259A adapter. You must use
adapter for IP Media Processor for 100-Mbps
speed.
The CAT3 cable that is used with C-LAN. You
must use a CAT5 or better for 100-Mbps speed.
CAUTION:
You must complete the following seven tasks before you freeze translations or save
translations to an MO disk that is used to read translations directly into a media
server. Failure to complete the tasks correctly can result in a system that does not
function.
CAUTION:
Be sure to do this step
before freezing translations.
Verify that the functions of
the TN577 Packet Gateway
and the TN726B Data Line
circuit packs (BX.25 links
and mode 2 data modules)
were converted to work
through the C-LAN circuit
packs.
Note that you cannot reuse the TN577 circuit pack.
Use Avaya Terminal Emulator or Avaya Site
Administration to perform a list node-names
command.
Be sure to do this step
before freezing translations.
Verify that the CMS and
INTUITY peripherals and
Distributed Communication
Service (DCS) links are
assigned node names and
an Ethernet address.
1 of 3