Configuring the Signal in the RF Domain
R&S
®
SMW200A
478User Manual 1175.6632.02 ─ 16
Remote command:
[:SOURce<hw>]:SWEep[:FREQuency]:EXECute on page 1113
[:SOURce<hw>]:SWEep:POWer:EXECute on page 1113
[:SOURce<hw>]:LFOutput:SWEep[:FREQuency]:EXECute on page 1071
:TRIGger<hw>[:SWEep][:IMMediate] on page 1148
:TRIGger<hw>:FSWeep[:IMMediate] on page 1148
:TRIGger<hw>:PSWeep[:IMMediate] on page 1148
:TRIGger<hw>:LFFSweep:IMMediate on page 1148
Reset Sweep
Resets a sweep.
With the next trigger event, the sweep starts at the initial value.
Remote command:
[:SOURce<hw>]:SWEep:RESet[:ALL] on page 1115
Start Frequency/Stop Frequency
Defines the frequency sweep range by setting the start and end values.
See Chapter 7.6.2.1, "Correlating Parameters in Sweep Mode", on page 467.
Remote command:
[:SOURce<hw>]:FREQuency:STARt on page 1045
[:SOURce<hw>]:FREQuency:STOP on page 1046
[:SOURce<hw>]:LFOutput:FREQuency:STARt on page 1065
[:SOURce<hw>]:LFOutput:FREQuency:STOP on page 1065
Start Level / Stop Level
Defines the level sweep range by setting the start and end values.
See Chapter 7.6.2.1, "Correlating Parameters in Sweep Mode", on page 467.
Remote command:
[:SOURce<hw>]:POWer:STARt on page 1100
[:SOURce<hw>]:POWer:STOP on page 1100
Center Frequency
In "RF Frequency Sweep" mode, sets the RF center frequency.
See Chapter 7.6.2.1, "Correlating Parameters in Sweep Mode", on page 467.
Remote command:
[:SOURce<hw>]:FREQuency:CENTer on page 1045
Span
In "RF Frequency Sweep" mode, sets the extent of the frequency sweep range.
See Chapter 7.6.2.1, "Correlating Parameters in Sweep Mode", on page 467.
Remote command:
[:SOURce<hw>]:FREQuency:SPAN on page 1045
Current Frequency
In "RF/LF Frequency Sweep" mode, displays the current frequency.
In Mode = "Step", the parameter is editable and you can enter the next frequency step.
Varying the RF Signal in List or Sweep Mode