Introduction
Issue 2.1 June 2006 1161
On the LSP’s primary controller
6. Verify that the media
gateway has registered
with the primary
controller.
See the "To verify
changes" subsection
under "Administering the
Media Gateway" in
Chapter 9.
● Open a SAT session and enter list
media-gateway. Verify that the Registered field
(Reg?) is set to y.
● Place a test call.
On the ICC/LSP
7. If IA770 is installed, get
IA770 data and stop
IA770.
See "Getting IA770
(AUDIX) data and
stopping IA770 (if IA770 is
being used)" in Chapter
12.
8. Record configuration
information.
See "Recording
configuration information"
in Chapter 11.
If you have not already done so, in the Record
Configuration Information task, record all of the
configuration information, regardless of the fact that you
are not upgrading Communication Manager.
You will re-enter some of this information after the
conversion.
9. Restore default server
configuration settings
On the Maintenance Web Interface, click Restore
Defaults under Server Configuration.
10. Set time, date, and time
zone.
See "Verifying Time, Date,
and Timezone" in Chapter
12.
The time of the LSP must be set to the same time zone as
its primary controller, even if the LSP is physically located
in a different time zone.
Task Steps/Comments
3 of 5