Loading...
Defaults Disabled.
Command
Modes
INTERFACE
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version 9.0.2.0 Introduced on the S6000.
Version
8.3.19.0
Introduced on the S4820T.
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 8.2.1.0 Introduced on S-Series Stacking.
Version 8.1.1.0 Introduced on the E-Series ExaScale.
Version 7.7.1.0 Introduced on the S-Series.
Version 7.6.1.0 Introduced on the C-Series.
Version 6.2.1.1 Introduced on the E-Series.
Usage
Information
When you enable sFlow on an interface, flow sampling is done on any traffic going
out of the interface.
NOTE: After a physical port is a member of a LAG, it inherits the sFlow
configuration from the LAG port.
Related
Commands
sflow enable (Global) — turns sFlow on globally.
sflow extended-switch enable
Enable packing information on a switch only.
S4810
Syntax
sflow extended-switch enable
To disable packing information, use the no sflow extended-switch [enable]
command.
Parameters
enable Enter the keyword enable to enable global extended
information.
sFlow