Example
Dell#show interfaces configured
GigabitEthernet 13/18 is up, line protocol is up
Hardware is Force10Eth, address is 00:01:e8:05:f7:fc
Current address is 00:01:e8:05:f7:fc
Interface index is 474791997
Internet address is 1.1.1.1/24
MTU 1554 bytes, IP MTU 1500 bytes
LineSpeed 1000 Mbit, Mode full duplex, Master
ARP type: ARPA, ARP Timeout 04:00:00
Last clearing of "show interfaces" counters 00:12:42
Queueing strategy: fifo
Input Statistics:
10 packets, 10000 bytes
0 Vlans
0 64-byte pkts, 0 over 64-byte pkts, 0 over 127-byte pkts
0 over 255-byte pkts, 10 over 511-byte pkts, 0 over 1023-
byte pkts
0 Multicasts, 0 Broadcasts
0 runts, 0 giants, 0 throttles
0 CRC, 0 overrun, 0 discarded
Output Statistics:
1 packets, 64 bytes, 0 underruns
1 64-byte pkts, 0 over 64-byte pkts, 0 over 127-byte pkts
0 over 255-byte pkts, 0 over 511-byte pkts, 0 over 1023-byte
pkts
0 Multicasts, 1 Broadcasts, 0 Unicasts
0 Vlans, 0 throttles, 0 discarded, 0 collisions
Rate info (interval 299 seconds):
Input 00.00 Mbits/sec, 0 packets/sec, 0.00% of line-rate
Output 00.00 Mbits/sec, 0 packets/sec, 0.00% of line-rate
Time since last interface status change: 00:04:59
Dell#
Related
Commands
show interfaces — displays information on a specific physical interface or virtual
interface.
show interfaces dampening
Display interface dampening information.
S4810
Syntax
show interfaces dampening [[interface] [summary] [detail]]
Parameters
interface (Optional) Enter one of the following keywords and slot/port
or number information:
For a Port Channel interface, enter the keywords port-
channel then a number. The range is from 1 to 128.
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port information.
For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE then the slot/port information.
summary (OPTIONAL) Enter the keyword summary to display the
current summary of dampening data, including the number
of interfaces configured and the number of interfaces
suppressed, if any.