Dell S4810 - Iscsi Profile-Compellant; Iscsi Target Port

Dell S4810
1761 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Version
8.3.16.0
Introduced on MXL 10/40GbE Switch IO Module.
iscsi profile-compellant
Configure the auto-detection of Dell Compellent arrays on a port.
S4810
Syntax
iscsi profile-compellent
Defaults Dell Compellent disk arrays are not detected.
Command
Modes
INTERFACE
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version
8.3.19.0
Introduced on the S4820T.
Version
8.3.12.0
Introduced on the S4810.
Version
8.3.16.0
Introduced on MXL 10/40GbE Switch IO Module.
iscsi target port
Configure the iSCSI target ports and optionally, the IP addresses on which iSCSI communication is
monitored.
S4810
Syntax
iscsi target port [tcp-port-2...tcp-port-16]ip-address [ip-
address]
To remove the configured iSCSI target ports or IP addresses, use the no iscsi
target port command.