EasyManua.ls Logo

Dell S4810 - Show Ethernet Cfm Maintenance-Points Local

Dell S4810
1761 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
name | level Enter the maintenance domain name or level.
brief Enter the keyword brief to display a summary output.
Defaults none
Command
Modes
EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version
8.3.19.0
Introduced on the S4820T.
Version 8.3.7.0 Introduced on the S4810.
Version 8.3.1.0 Introduced on the S-Series.
Example
Dell# show ethernet cfm domain
Domain Name: customer
Level: 7
Total Service: 1
Services
MA-Name VLAN CC-Int X-CHK Status
My_MA 200 10s enabled
Domain Name: My_Domain
Level: 6
Total Service: 1
Services
MA-Name VLAN CC-Int X-CHK Status
Your_MA 100 10s enabled
show ethernet cfm maintenance-points local
Display configured MEPs and MIPs.
S4810
Syntax
show ethernet cfm maintenance-points local [mep | mip]
Parameters
mep Enter the keyword mep to display configured MEPs.
mip Enter the keyword mip to display configured MIPs.