Version 9.2(0.0) Introduced on the M I/O Aggregator. This command is
supported in Programmable-Mux (PMUX) mode only.
Version
8.3.19.0
Introduced on the S4820T.
Version
8.3.12.0
Introduced on the S4810.
Version 8.4.2.3 Introduced on the S-Series S50.
Related
Commands
clear ufd-disable — re-enables downstream interfaces that are in a UFD-Disabled
Error state.
description
Enter a text description of an uplink-state group.
S4810
Syntax
description text
Parameters
text Text description of the uplink-state group. The maximum
length is 80 alphanumeric characters.
Defaults none
Command
Modes
UPLINK-STATE-GROUP
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version 9.2(0.0) Introduced on the M I/O Aggregator. This command is
supported in Programmable-Mux (PMUX) mode only.
Version
8.3.19.0
Introduced on the S4820T.
Version
8.3.12.0
Introduced on the S4810.
Version 8.4.2.3 Introduced on the S-Series S50.
Example
Dell(conf-uplink-state-group-16)# description test
Dell(conf-uplink-state-group-16)#
Uplink Failure Detection (UFD)