show range — shows the bulk configuration ranges.
interface range macro (define) — defines a macro for an interface-range.
interface range macro (define)
Defines a macro for an interface range and then saves the macro in the running configuration.
S4810
Syntax
define interface range macro name interface , interface , ...
Parameters
name Enter up to 16 characters for the macro name.
interface,
interface,...
Enter the keywords interface range and one of the
interfaces — slot/port, port-channel, or VLAN number. Select
the range of interfaces for bulk configuration. You can enter
up to six comma-separated ranges. Spaces are not required
between the commas. Comma-separated ranges can
include VLANs, port-channels, and physical interfaces.
Slot/Port information must contain a space before and after
the dash. For example, interface range
gigabitethernet 0/1 - 5 is valid; interface range
gigabitethernet 0/1-5 is NOT valid.
For a 1-Gigabit Ethernet interface, enter the keyword
GigabitEthernet then the slot/port information.
For a Port Channel interface, enter the keywords port-
channel
then a number. The range is from 1 to 128.
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port information.
For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE then the slot/port information.
For a Tunnel interface, enter the keyword tunnel then
the tunnel ID. The range is from 1 to 16383.
For a VLAN, enter the keyword vlan followed by a
number from 1 to 4094.
Defaults none
Command
Modes
CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version 9.0.2.0 Introduced on the S6000.
Interfaces
757

Table of Contents

Other manuals for Dell S4810

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell S4810 and is the answer not in the manual?

Dell S4810 Specifications

General IconGeneral
Ports48 x 10GbE SFP+
Uplink Ports4 x 40GbE QSFP+
Switching Capacity1.28 Tbps
Rack Units1U
Product TypeSwitch
Form FactorRack-mountable
Power DeviceInternal power supply
Power RedundancyYes
Operating Temperature0°C to 40°C
Storage Temperature-40°C to 70°C
Power SupplyDual, hot-swappable
MAC Address Table Size128, 000 entries
Routing ProtocolOSPF, BGP, RIP, PIM, VRRP
Remote Management ProtocolSNMP
FeaturesVLAN, QoS
Humidity10% to 90% non-condensing
Dimensions (WxDxH)43.9 x 46.5 x 4.3 cm

Related product manuals