UMN:CLI User Manual
V5808
110
(unit: minutes, default: Mar 10 2:00-
Nov 10 2:00, offset : 60 minites)
Deletes the configured daylight
saving time.
To display the configured daylight saving time, use the following command.
Shows the configured summer time.
The following example sets system time from 12:00, August 18, 2013 to 12:00, August 20,
2013.
SWITCH(config)# time-zone GMT+9
SWITCH(config)# clock summer-time GMT+9 date 18 8 2013 12:00 20 8 2013 12:00
60
SWITCH(config)# show clock summer-time
=============================================
Summer time is set. But not running.
---------------------------------------------
Summer time type : this year only
---------------------------------------------
Start time : 2013 aug 18 12:00
Stop time : 2013 aug 20 12:00
=============================================
SWITCH(config)#
6.1.3 Time Zone
The V5808 provides three kinds of time zone, GMT, UCT and UTC. The time zone of the
switch is predefined as GMT (Greenwich Mean Time). You can also set the time zone
where the network element belongs.
To set the time zone, use the following command.
Sets the time zone (refer to the below table).
Clears a configured time zone.
To display the world time zone, use the following command.
Shows the world time zone map.