663
1-30: aging time measured in days
onu inactive aging-time disable
Sets the ONU aging time to be unlimited (default)
To display the configured aging time for the inactive ONUs, use the following command.
Command
Mode
Description
show onu inactive aging-time
[OLT-ID]
Enable
Global
GPON
Shows the configured aging time for the inactive
ONUs.
show onu inactive aging-time
GPON-OLT
You can monitor how long the ONU has been inactive status displayed in the Inactive
Time field using show onu detail-info command. If the ONUs activation status is active,
the inactive time value remains unchanged at 0:00:00:00.
12.2.14 ONU Reset
For various reasons such as HW or SW error, you may need to reset an ONU (ONT). To
reset an ONU, use the following command.
Command
Mode
Description
onu reset ONU-IDs
GPON-OLT
Reboots a specific ONU.
ONU-ID: ONU ID (1 to128) or ONU serial number
onu restore-factory reset ONU-
IDs
Restores the factory default settings of ONU.
ONU-ID: ONU ID (1 to128) or ONU serial number
onu re-config ONU-ID
Resets the ONU for delete the ONU’s MAC table.
12.2.15 ONU Password Type Configuration
To configure ONU password type, use the following command.
Command
Mode
Description
onu password-type {hex | ascii}
GPON
Configures ONU password type.
12.2.16 Diagnostic Monitoring for ONUs Optical Transceiver
The Digital Diagnostic Monitoring Interface (DDMI) feature provides diagnostic
information about the modules present operating conditions. The transceiver generates
this diagnostic data by digitization of internal analog signals.
To display the operating parameters of ONUs GPON module, use the following command.
Command
Mode
Description

Table of Contents