EasyManua.ls Logo

Dasan V5808 - Maximal Distance between OLT and ONU (ONT); Forward Error Correction (FEC) Mode

Dasan V5808
814 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual UMN:CLI
V5808
631
ONUs laser permanently.)
To display a current configuration of the auto ONU fault detection, use the following
command.
Command
Mode
Description
show olt signal-check OLT-ID
Enable
Global
GPON
Shows a current configuration of the auto ONU (ONT)
fault detection.
show olt signal-check
GPON-OLT
To guarantee a right operation of this feature, the OLT and an ONU (ONT) loaded with the
newest firmware are needed.
12.1.5 Maximal Distance between OLT and ONU (ONT)
PON systems distribute the bandwidth of each fiber core among up to 64 (max.128) line
termination points using splitters. The actual maximum distance between OLT and ONU
(ONT) is typically 20 km. The logical handling of GPON data streams however allows a
distance of up to 60 km.
To determine maximal GPON distance between OLT and ONU (ONT), use the following
command.
Command
Mode
Description
olt max-distance default
GPON-OLT
Determine maximal distance between OLT and ONU.
default: 0-20km
20-60: maximal distance (km)
olt max-distance <20-60>
12.1.6 Forward Error Correction (FEC) Mode
Forward Error Correction (FEC) feature can improve the quality and reach of an optical
link. FEC is implemented according to G984.3 standard, which defines the use of the
code which is able to protect 239 bytes of the payload with 16 redundant bytes, allowing
the receiver to detect and correct transmission errors.
To enable/disable downstream FEC mode, use the following command.
Command
Mode
Description
olt fec-mode ds enable
GPON-OLT
Enables downstream FEC mode per OLT ID.
olt fec-mode ds disable
Disables downstream FEC mode per OLT ID.
To enable/disable upstream FEC mode, use the following command.
Command
Mode
Description
!