User Manual UMN:CLI
V5808
119
LOW_VALUE: underload system temperature (-40 to
100°C, default: -20°C)
Deletes a configured threshold of system temperature.
To display the configured threshold of system temperature, use the following command.
Shows the status and configured threshold of system
temperature.
6.1.13.5 System Memory
To set the threshold of system memory in use, use the following command.
threshold memory <20-100>
Sets the threshold of system memory in the unit of
percent (%).
20-100: system memory in use
Deletes the configured threshold of system memory.
6.1.13.6 System/SFP Module Operation
The system/SFP module will operate depending on monitoring type of temperaturem,
RX/TX power, voltage or Txbias.
To set the threshold of module, use the following command.
threshold module {rxpower |
txpower} {alarm | warning}
PORTS {START-VALUE STOP-
VALUE | operational}
Sets the Diagnostics threshold of SFP module by
RX/TX power and monitors the module
The range of RX/TX power: -40 to 8.1647 dBm
threshold module temper {alarm
| warning} PORTS {START-
VALUE STOP-VALUE |
operational}
Sets the Diagnostics threshold of SFP module
depending on temperature and monitors the module.
The range of temperature: -128 to 127.99℃
threshold module txbias {alarm |
warning} PORTS {START-VALUE
STOP-VALUE | operational}
Sets the Diagnostics threshold of SFP module
depending on txbias and monitors the module.
The range of txbias: 0 ∼ 131 mA
threshold module voltage {alarm
| warning} PORTS {START-
VALUE STOP-VALUE |
operational}
Sets the Diagnostics threshold of SFP module
depending on voltage and monitors the module.
The range of voltage: 0 to 6.5535 V
To delete the threshold of module operation depending on specified monitoring type, use
the following command.