You can also set the blocking timer. When incoming traffic via a given port exceeds a
configured threshold, the port will discard that traffic during a specified time.
To set the blocking timer, use the following command.
Command
Mode
Description
threshold port PORTS block
timer <10-3600>
Global
Sets the blocking timer.
PORTS: port number
10-3600: blocking time (unit: second)
no threshold port PORTS block
Disables the blocking timer
To display the configured threshold of port traffic, use the following command.
Command
Mode
Description
show port threshold
Enable
Global
Bridge
Shows the configured threshold of port traffic.
6.1.13.3 Fan Operation
The system fan will operate depending on measured system temperature. To set the
threshold of fan operation, use the following command.
Command
Mode
Description
threshold fan START-TEMP
STOP-TEMP
Global
Sets the threshold of fan operation in the unit of
Celsius (°C).
START-TEMP: starts fan operation. (default: 30)
STOP-TEMP: stops fan operation. (default: 0)
no threshold fan
Deletes a configured threshold of fan operation.
When you set the threshold of fan operation, START-TEMP must be higher than STOP-
TEMP.
To display the configured threshold of fan operation, use the following command.
Command
Mode
Description
show status fan
Enable/Global/Bridge
Shows the status and configured threshold of fan
operation.
6.1.13.4 System Temperature
To set the threshold of system temperature, use the following command.
Command
Mode
Description
threshold temp HIGH_VALUE
LOW_VALUE
Global
Sets the threshold of system temperature(°C).
HIGH_VALUE: overload system temperature (-40 to
100°C, default: 80°C)
!

Table of Contents