User Manual UMN:CLI
V5808
165
To configure the first alarm to occur when object is firstly more than threshold or less than
threshold, use the following command.
startup-type rising-and-falling
Configures the first Alarm to occur when object is firstly
more than threshold or less than threshold.
7.3.2.7 Interval of Sample Inquiry
The interval of sample inquiry means time interval to compare selected sample data with
upper bound of threshold or lower bound of threshold in terns of seconds.
To configure interval of sample inquiry for RMON alarm, use the following command.
sample-interval <0-65535>
Configures interval of sample inquiry.
(unit: second)
7.3.2.8 Activating RMON Alarm
After finishing all configurations, you need to activate RMON alarm. To activate RMON
alarm, use the following command.
7.3.2.9 Deleting Configuration of RMON Alarm
When you need to change a configuration of RMON alarm, you should delete an existing
RMON alarm.
To delete RMON alarm, use the following command.
Deletes RMON history of specified number, enter the
value for deleting.
7.3.3 RMON Event
RMON event identifies all operations such as RMON alarm in the switch. You can
configure event or trap message to be sent to SNMP management server when sending
RMON alarm.
You need to open RMON Event Configuration mode to configure RMON event.
Opens RMON Event Configuration mode.
1-65535: index number