The important features provided by 802.1ag CFM OAM are:
Supports Connectivity Check Message (CCM), LinkTrace (LTM) and LoopBack
messages (LBM)
Helps service providers assign selected subscribers restricted access to manage all
functions for their own domains
Fault detection, notification and verification
Traces the path to another MEP or MIP in the same domain
A CFM maintenance domain (MD) is a management space on a network that is owned
and operated by a single entity and defined by a set of ports internal to it, but at its
boundary. To use CFM OAM, you should create MD. MD is defined by a given MD name
and level that are configured by user. MD level determines the MEPs/MIPs that are
interested in the contents of the CFM frame and through which the CFM frame is allowed
to pass.
To create a CFM Maintenance Domain (MD) and configure its name and level, use the
following command.
Command
Mode
Description
onu cfm md DOMAIN level <0-7>
GPON
Creates a MD name and specifies a MDs level
DOMAIN: Maintenance Domains name
0-7: MDs level to use (default: 0)
no onu cfm md DOMAIN
Deletes the configured MD with a unique name.
Each MD has an index, an unique name and MD level. Several MDs can have same level.
But one single MD cannot have several levels.
MEPs periodically exchange Continuity Check OAM messages to detect loss of continuity
or incorrect network connections. To create a Maintenance Association (MA) with its
name as a service instance for a specific MD and specify the interval of Continuity Check
Messages (CCMs) that are sent by MEPs in the specified MA, use the following
command.
Command
Mode
Description
onu cfm ma <1-65535> MA_NAME md
DOMAIN ccm interval { 100ms | 1s |
10s | 1m | 10m | disable }
GPON
Specifies a MA for MD and the interval of
sending continuity check messages (CCMs).
1-65535: MA index
MA_NAME: name of MA
DOMAIN: Maintenance Domains name
no onu cfm ma <1-65535>
Deletes the configured MA.
There is at least one MA within a signle MD.
To configure a MIP and its level on the VLAN ID, use the following command.