UMN:CLI User Manual
V5808
734
12.4.7.2 Framing Structure
To specify the framing structure, use the following command.
framing { extend-superframe | superframe |
unframed | g-704 | jt-g-704 | basic-g-704 |
basic-crc4 | basic-ts16 | basic-crc4-ts16 }
Specifies the framing structure.
(mandatory for DS1 interfaces)
12.4.7.3 Encoding
To specify the line coding scheme, use the following command.
encoding { b8zs | ami | hdb3 |
b3zs }
Specifies the line coding scheme. (mandatory for DS1
and DS3 interfaces)
b8zs: B8ZS , ami: AMI
hdb3: HDB3
b3zs: B3ZS
12.4.7.4 Line Length
To specify the cable line length with power feed, use the following command.
line-length power-feed ds1-non-
power line-length { 110 | 220 |
330 | 440 | 550 | 660 }
Specifies the length of the twisted pair cable from a
DS1 physical UNI to the DSX-1 cross-connect point.
ds1-non-power: non-power feed type DS1
110~660: line length (unit: ft) (110: 0 to 110, 660: 550 to
660)
ds1-power-short: power feed type DS1 (Wet T1), short
haul
133~655: line length (unit: ft) (133: 0 to 133, 655: 533
to 655)
ds1-power-long: power feed type DS1 (Wet T1), long
haul
0/7_5/15/22_5: line length (unit: db) (7_5: 7.5, 22_5:
22.5)
line-length power-feed ds1-
power-short line-length { 133 |
266 | 399 | 533 | 655 }
line-length power-feed ds1-
power-long line-length { 0 | 7_5 |
15 | 22_5 }
line-length power-feed ds3-
power line-length { 225 | 450 }
Specifies the length of coaxial cable from a DS3
physical UNI to the DSX-3 cross-connect point.
ds3-power: DS3 power feed
225/450: line length (unit: ft) (225: 0 to 225, 450: 226 to
450)
Deletes the configured line length.